  • Continuous volume flow measurement according to the differential pressure principle with two chamber measuring probe.
  • Special lengths available up to max. 8 m
  • Average measurement across whole stack.
  • Applications up to 600°C; special versions in Hasteloy or Inconel.
  • Differential pressure transducer direct on the probe or via flexible tube connection.
  • Measuring range 3...40 m/s. Conversion to normalised volume flow in Nm3/h
  • Typical applications: measurement of volume flow in ducts and flue stacks
Measuring Method

The D-FL 100 Measuring System works according to the principle of mechanical effect. The probe has two separate chambers, between which a pressure difference, caused by the flow in the duct, builds up. The differential pressure resulting at the probe is proportional to the square of the gas speed. Due to the probe’s special shape, a highest possible differential pressure is produced, whereby the linearity of the measuring signal is guaranteed.

On this basis, and taking the other flow parameters into account, the volume flow can be converted from operational to standard conditions by the D-FL 100-10 Microprocessor Evaluation Unit. For this purpose, two additional current inputs (0-20 mA) for a temperature probe and a pressure probe have been provided for at the evaluation unit. If an emission evaluation computer is available, which can compensate the pressure and temperature-dependence of the gases and that calculates the actual corrected value of the volume flow, the evaluation unit is not needed.

Application

According to TA-Luft pollutant emissions of industrial plants must be monitored. For mass determination of the pollutants, also the exhaust gas flow must be measured with the help of a measuring device.

The DURAG D-FL 100 Measuring System continuously determines the flow velocity and the flow rate of the exhaust gas. Preselectable limit value surpassings are indicated inertia-free, so permitting necessary interventions in the plant control system so as to comply with prescribed emission limit values.

Registration

Type tested to the guidelines of the Federal Ministry for Environment, Nature Conservation and Reactor Safety on suitability testing of measuring equipment for continuous measuring of emissions

Test report #128CU11650 of TÜV Nord, Hamburg

Itemized in the list of suitable measuring instru-ments for continuous registration of emissions GMBI #42 of 1996

 

   

 

 