- Measuring ranges 0-0,1...1,6 Ext
or 0-20...100% opacity
- Can be calibrated to mg/m3:
0-300...5000 mg/m3 per meter measuring distance
- For measurement of opacity
installation without calibration
- Measuring path length: 0,5 - 14 m
- Automatic soiling correction,
automatic zero and control point check.
- Typical applications: smoke
density measurement in heating plants, dust concentration
measurement in flue gas of Power plants, Steel and Blast Furnace
Plants, Cement Plants, Refineries etc.
- Compliant to US EPA
regulations
|
| Measuring Method |
|
The instrument applies the 2-beam alternate light
method following the autocollimation principle, i.e., the lightbeam
crosses the measuring section twice. The unit measures and evaluates
the light beam's weakening caused by the dust content within the
measuring section.
Switching between the measuring beam and a comparator
light beam proceeds through an electromagnetically actuated rotary
diaphragm. For check value compensation, comparative measurings of 2
seconds duration each occur every 2 minutes. A photoelement
alternatingly receives the measuring and the comparator light beam.
There is only 1 joint amplifier for the measuring and the comparator
beams, thus compensating for ageing of the bulb and the photo
element, for temperature influences as well as for amplifier
long-term drift. The monochromatic emitter light is being modulated
with 1.2 kHz, avoiding influence of constant light (daylight, etc.).
The core piece of the D-R 281 AV is a randomly programmable
microprocessor. A 64" integral can be activated by way of a jumper
in the terminal box. It works floatingly and effects a settled
indication. There are 5 measuring ranges switchable between 0.1,
-0.2, -0.4, -0.8, -1.6 ext.
For proper functioning the D-R 280 performs a check
cycle every 2 hours, thereby measuring and indicating the zero
point, the soiling of the optical boundary surfaces as well as a
reference value automatically. If necessary, the subsequent
measuring values will be corrected. If the correction surpasses a
determinated value, an error signal will be generated. |
| Application |
|
The DURAG D-R 281 AV Dust Concentration Meter is used
for continuous dust measuring in flue gas chimneys and dust
extraction pipings. According to TA Luft and 13. BlmSchV it is
suitable for
- furnace plants with hard coal, brown coal, fuel oil and
mix-type combustions
- converter plants, asphalt mixing plants and cement
production plants
- as well as for any other type of plant requiring
quantitative measuring of dust concentrations.
|
Registration |
|
Type tested to the guidelines for emission measuring
equipments of the Federal Ministry of Interior - FMI Circular UII
8-556134/4 dated 21.7.1980
by TÜV Rheinland Technical Ins-pection Agency, Test
Report # 936/802002-2 of 10.12.82,
itemized in the list of suitable instruments for
continuous registration of emissions. Joint Ga-zette # 16 of
15.6.1983 of the Federal Ministry of
Interior. |
|
|
| |
|
|
|